Interlaboratory Comparison Of Cavity Resonator Measurements For Complex Permittivity To 170 GHz

Department of Commerce

@usgov.doc_gov_interlaboratory_comparison_of_cavity_resonator_fb778bbd

Loading...
Loading...

About this Dataset

Interlaboratory Comparison Of Cavity Resonator Measurements For Complex Permittivity To 170 GHz

Figure data for "Interlaboratory comparison of cavity resonator measurements for complex permittivity to 170 GHz"ABSTRACT:Standards provide known right answers traceable to National Metrology Institutes. Today, no such complex permittivity standard exists, let alone one traceable to the International System of Units (SI). In response, a consortium of industrial, academic, and government laboratories - led by the International Electronics Manufacturing Initiative (iNEMI) - performed an interlaboratory comparison to understand the impact of this problem and how a new standard could help. The goal of the comparison was to benchmark the best-case interlaboratory agreement in complex permittivity measurements up to 170 GHz and provide some industry-led guidance for making the standard useful. The consortium used four different types of commercial resonators from 10 GHz to 170 GHz. Here, we show how we improved the best-case repeatability and interlaboratory agreement of these resonator measurements. We leverage the broader capabilities of nine industry (e.g., Intel, Panasonic, 3M) and government (e.g., NIST, ITRI) labs worldwide in the four interlaboratory comparisons presented here. These interlaboratory comparisons quantify interlaboratory agreement and incorporate stakeholder feedback to develop a fit-for-purpose standard for complex permittivity.
Organization: Department of Commerce
Last updated: 2025-09-30T05:41:32.902231
Tags: dielectrics, interlaboratory-comparison, permittivity

Tables

Figure10DataAgg

@usgov.doc_gov_interlaboratory_comparison_of_cavity_resonator_fb778bbd.figure10dataagg
  • 13.64 kB
  • 132 rows
  • 7 columns
Loading...

Figure5DataAgg

@usgov.doc_gov_interlaboratory_comparison_of_cavity_resonator_fb778bbd.figure5dataagg
  • 10.01 kB
  • 117 rows
  • 7 columns
Loading...

Figure6DataAgg

@usgov.doc_gov_interlaboratory_comparison_of_cavity_resonator_fb778bbd.figure6dataagg
  • 6.98 kB
  • 58 rows
  • 7 columns
Loading...

Figure7DataAgg

@usgov.doc_gov_interlaboratory_comparison_of_cavity_resonator_fb778bbd.figure7dataagg
  • 18.63 kB
  • 214 rows
  • 7 columns
Loading...

Figure8DataAgg

@usgov.doc_gov_interlaboratory_comparison_of_cavity_resonator_fb778bbd.figure8dataagg
  • 13.46 kB
  • 175 rows
  • 7 columns
Loading...

Figure9DataAgg

@usgov.doc_gov_interlaboratory_comparison_of_cavity_resonator_fb778bbd.figure9dataagg
  • 15.11 kB
  • 163 rows
  • 7 columns
Loading...

Share link

Anyone who has the link will be able to view this.