We investigated the influence of the state of wear of Charpy machine anvils on test results by performing impact tests on NIST specimens of three energy levels with a machine equipped with new anvils (compliant with both ASTM E23 and ISO 148-2) and worn anvils (anvil corner radii and distance outside ASTM tolerances, but within ISO tolerances).
Organization: National Institute of Standards and Technology
Organization URL: https://catalog.data.gov/organization/nist
Last updated: 2020-01-24 00:00:00
Tags: ASTM E23, Absorbed energy, Charpy, ISO 148, machine anvils, span, wear