Baselight is shutting down June 30.
Export any data that you want to keep. Read the announcement.
National Institute of Standards and Technology
Dataset Description
These data from the laboratory tests of a prototype residential liquid-to-air ground-source air conditioner (GSAC) using CO2 as the refrigerant. The data collection and processing methods are described in detail in this report:
Report Title: "Laboratory Tests of a Prototype Carbon Dioxide Ground-Source Air Conditioner", NIST Technical Note 2068
Publication Date: October 2019
DOI: https://doi.org/10.6028/NIST.TN.2068
Authors: Harrison Skye, Wei Wu
The tests were performed in an environmental chamber and followed the ISO 13256-1 standard for rating GSHPs. The CO2 GSAC operated either in a subcritical or a transcritical cycle, depending on the entering liquid temperature (ELT). The test results included the coefficient of performance (COP), capacity, sensible heat ratio (SHR), and pressures. The system incorporated a liquid-line/suction-line heat exchanger (LLSL-HX), which was estimated to cause a COP penalty of (0 to 2) % for ELTs ranging (10 to 25) °C, and benefit of (0 to 5) % for ELTs ranging (30 to 39) °C. With ELTs ranging (10 to 39) °C the CO2 system cooling COP ranged (7.3 to 2.4). At the standard rating condition (ELT 25 °C), the CO2 GSAC cooling COP was 4.14, and at part-load conditions (ELT 20 °C) the system had a COP of 4.92.
Organization: National Institute of Standards and Technology
Organization URL: https://catalog.data.gov/organization/nist
Last updated: 2019-10-11 00:00:00
Tags: Air conditioner, CO2, carbon dioxide, ground-source heat pump, subcritical and transcritical cycles