Baselight

AM Bench 2022 ASTM E8 Macroscale Tension At Different Strain Rates On As-built IN625

National Institute of Standards and Technology

@usgov.national_institute_of_standard_am_bench_2022_astm_e8_m_de29adf6

Loading...
Loading...

About this Dataset

AM Bench 2022 ASTM E8 Macroscale Tension At Different Strain Rates On As-built IN625

Macro-scale tensile data on additively manufactured (AM) IN625 in the as-built microstructural condition at room temperature and at different strain rates are provided in this data publication. The specimens are machined in accordance with ASTM-E8 subsize specimen with a gauge width of 6 mm and a gauge thickness of 4 mm. Three specimens are tested at a nominal strain rate of 0.001 1/s and 2 specimens are tested at a nominal strain rate of 0.01 1/s on a servo hydraulic material testing machine using a constant crosshead displacement rate of 0.03175 mm/s and 0.3175 mm/s, respectively. Stereo digital image correlation (DIC) is used to report a 25.4 mm gauge length virtual extensometer strain up to fracture for each experiment. A separate comma-separated-value (csv) file for each experiment is provided which contains time, engineering strain, and engineering stress data. The first row in the csv file gives the column name. The second row in the csv file gives the SI unit of the column. Please see SUMMARY_AMBench_2022_Tensile_data.pdf file for further details regarding the additive manufacturing procedures of the specimens, the composition of the IN625, and the measurements.
Organization: National Institute of Standards and Technology
Last updated: 2023-03-18T13:07:44.283130
Tags: additive-manufacturing, am-bench, benchmark, inconel-625, mechanical-characterization, strain-rate, superalloy

Tables

T3 Data File

@usgov.national_institute_of_standard_am_bench_2022_astm_e8_m_de29adf6.t3_data_file
  • 18.66 KB
  • 689 rows
  • 3 columns
Loading...

CREATE TABLE t3_data_file (
  "time" VARCHAR,
  "engineering_strain" VARCHAR,
  "engineering_stress" VARCHAR
);

T4 Data File

@usgov.national_institute_of_standard_am_bench_2022_astm_e8_m_de29adf6.t4_data_file
  • 18.42 KB
  • 659 rows
  • 3 columns
Loading...

CREATE TABLE t4_data_file (
  "time" VARCHAR,
  "engineering_strain" VARCHAR,
  "engineering_stress" VARCHAR
);

T5 Data File

@usgov.national_institute_of_standard_am_bench_2022_astm_e8_m_de29adf6.t5_data_file
  • 20.55 KB
  • 775 rows
  • 3 columns
Loading...

CREATE TABLE t5_data_file (
  "time" VARCHAR,
  "engineering_strain" VARCHAR,
  "engineering_stress" VARCHAR
);

T6 Data File

@usgov.national_institute_of_standard_am_bench_2022_astm_e8_m_de29adf6.t6_data_file
  • 18.61 KB
  • 685 rows
  • 3 columns
Loading...

CREATE TABLE t6_data_file (
  "time" VARCHAR,
  "engineering_strain" VARCHAR,
  "engineering_stress" VARCHAR
);

T7 Data File

@usgov.national_institute_of_standard_am_bench_2022_astm_e8_m_de29adf6.t7_data_file
  • 20.09 KB
  • 759 rows
  • 3 columns
Loading...

CREATE TABLE t7_data_file (
  "time" VARCHAR,
  "engineering_strain" VARCHAR,
  "engineering_stress" VARCHAR
);

Share link

Anyone who has the link will be able to view this.