Baselight

ASHRAE Global Occupant Behavior Database

Data from 32 research studies focused on occupancy interactions with spaces

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database

Loading...
Loading...

About this Dataset

ASHRAE Global Occupant Behavior Database

Dataset and documentation: https://ashraeobdatabase.com

Context

The ASHRAE Global Occupant Behavior Database was developed by Wei Mu, Yapan Liu and Bing Dong (Syracuse University), Tianzhen Hong (LBNL), Bjarne W. Olesen (Technical University of Denmark), Tom Lawrence (University of Georgia) and Zheng O’Neill (Texas A&M University) as part of the ASHRAE MTG.OBB research grant URP-1883.

Content

Study_ID Behavior_Type Publication
1 Door_Status Korsavi, S. S., Montazami, A., & Brusey, J. (2018). Developing a design framework to facilitate adaptive behaviours. Energy and Buildings, 179, 360-373. https://doi.org/10.1016/j.enbuild.2018.09.011
Fan_Status
Occupant_Number
Occupancy
Shading_Status
Window_Status
2 Appliance_Usage Rafsanjani, H. N., Ahn, C. R., & Chen, J. (2018). Linking building energy consumption with occupants' energy-consuming behaviors in commercial buildings: Non-intrusive occupant load monitoring (NIOLM). Energy and Buildings, 172, 317-327. https://doi.org/10.1016/j.enbuild.2018.05.007
3 Door_Status Kumar, S., Singh, M. K., Kukreja, R., Chaurasiya, S. K., & Gupta, V. K. (2019). Comparative study of thermal comfort and adaptive actions for modern and traditional multi-storey naturally ventilated hostel buildings during monsoon season in India. Journal of Building Engineering, 23, 90-106. https://doi.org/10.1016/j.jobe.2019.01.020
Fan_Status
Window_Status
4 HVAC_Measurement Schwee, J. H., Johansen, A., Jørgensen, B. N., Kjærgaard, M. B., Mattera, C. G., Sangogboye, F. C., & Veje, C. (2019). Room-level occupant counts and environmental quality from heterogeneous sensing modalities in a smart building. Scientific data, 6(1), 1-11. https://doi.org/10.1038/s41597-019-0274-4
Occupant_Number
5 Appliance_Usage Piselli, C., & Pisello, A. L. (2019). Occupant behavior long-term continuous monitoring integrated to prediction models: Impact on office building energy performance. Energy, 176, 667-681. https://doi.org/10.1016/j.energy.2019.04.005
Door_Status
Window_Status
8 Door_Status Touchie, M. F., & Pressnail, K. D. (2014). Using suite energy-use and interior condition data to improve energy modeling of a 1960s MURB. Energy and buildings, 80, 184-194. http://doi.org/10.1016/j.enbuild.2014.05.014
Window_Status
9 Lighting_Status Bursill, J. (2020). An Approach to Data-Driven Sensing and Predictive Supervisory Control for Commercial Buildings with In-Situ Evaluation (Doctoral dissertation, Carleton University). https://doi.org/10.22215/etd/2020-14103
Occupancy
10 Appliance_Usage Mora, D., Fajilla, G., Austin, M. C., & De Simone, M. (2019). Occupancy patterns obtained by heuristic approaches: cluster analysis and logical flowcharts. A case study in a university office. Energy and Buildings, 186, 147-168. https://doi.org/10.1016/j.enbuild.2019.01.023
Door_Status
HVAC_Measurement
Occupancy
Occupant_Number
Window_Status
11 Occupancy Dong, B., Li, Z., & Mcfadden, G. (2015). An investigation on energy-related occupancy behavior for low-income residential buildings. Science and Technology for the Built Environment, 21(6), 892-901. http://doi.org/10.1080/23744731.2015.1040321
13 HVAC_Measurement Bandurski, K., Hamerla, M., Szulc, J., & Koczyk, H. (2017). The influence of multifamily apartment building occupants on energy and water consumption-the preliminary results of monitoring and survey campaign. In E3S Web of Conferences (Vol. 22, p. 00010). EDP Sciences. https://doi.org/10.1051/e3sconf/20172200010
18 Appliance_Usage Das, A., Annaqeeb, M. K., Azar, E., Novakovic, V., & Kjærgaard, M. B. (2020). Occupant-centric miscellaneous electric loads prediction in buildings using state-of-the-art deep learning methods. Applied Energy, 269, 115135. https://doi.org/10.1016/j.apenergy.2020.115135
Occupancy
19 Fan_Status Lipczynska, A., Schiavon, S., & Graham, L. T. (2018). Thermal comfort and self-reported productivity in an office with ceiling fans in the tropics. Building and Environment, 135, 202-212. https://doi.org/10.1016/j.buildenv.2018.03.013
HVAC_Measurement
Window_Status
20 Appliance_Usage Mahdavi, A., Berger, C., Tahmasebi, F., & Schuss, M. (2019). Monitored data on occupants' presence and actions in an office building. Scientific data, 6(1), 1-5. https://doi.org/10.1038/s41597-019-0271-7
22 Appliance_Usage Sonta, A., Dougherty, T. R., & Jain, R. K. (2021). Data-driven optimization of building layouts for energy efficiency. Energy and Buildings, 238, 110815. https://doi.org/10.1016/j.enbuild.2021.110815
23 HVAC_Measurement Neves, L. O., Hopes, A. P., Chung, W. J., & Natarajan, S. (2020). "Mind reading" building operation behaviour. Energy for Sustainable Development, 56, 1-18. https://doi.org/10.1016/j.esd.2020.02.003
Window_Status
24 Occupancy Schweiker, M., Kleber, M., & Wagner, A. (2019). Long-term monitoring data from a naturally ventilated office building. Scientific data, 6(1), 1-6. https://doi.org/10.1038/s41597-019-0283-3
Window_Status
25 HVAC_Measurement Rupp, Ricardo Forgiarini; Andersen, R.K.; Toftum, J.; Ghisi, E. (2021). Occupant behaviour in mixed-mode office buildings in a subtropical climate: Beyond typical models of adaptive actions https://doi.org/10.1016/j.buildenv.2020.107541
26 Door_Status Langevin, J. (2019). Longitudinal dataset of human-building interactions in US offices. Scientific data, 6(1), 1-10. https://doi.org/10.1038/s41597-019-0273-5
Fan_Status
HVAC_Measurement
Shading_Status
Window_Status
27 Other_HeatWave Andrews, Clinton & Mainelis, Gediminas & (co-Pi, Richard & Sorensen Allacci, Maryann & Plotnik, Deborah & Senick, Jennifer & Feygina, Irina & Autote, Olga & Ramkumar, Swetha & Pryce, Tiffany & Marathe, Rewa & Ding, Jiayi. (2013). Expanding the Definition of Green - Impacts of Green and Active Living Design on Health in Low Income Housing: Added Value of Behavioral Interventions as part of an Integrated Service Delivery Model.
28 Other_Role of habits in consumption Andrews, Clinton & Mainelis, Gediminas & (co-Pi, Richard & Sorensen Allacci, Maryann & Plotnik, Deborah & Senick, Jennifer & Feygina, Irina & Autote, Olga & Ramkumar, Swetha & Pryce, Tiffany & Marathe, Rewa & Ding, Jiayi. (2013). Expanding the Definition of Green - Impacts of Green and Active Living Design on Health in Low Income Housing: Added Value of Behavioral Interventions as part of an Integrated Service Delivery Model.
29 Other_IAQ in Affordable Housing Andrews, Clinton & Mainelis, Gediminas & (co-Pi, Richard & Sorensen Allacci, Maryann & Plotnik, Deborah & Senick, Jennifer & Feygina, Irina & Autote, Olga & Ramkumar, Swetha & Pryce, Tiffany & Marathe, Rewa & Ding, Jiayi. (2013). Expanding the Definition of Green - Impacts of Green and Active Living Design on Health in Low Income Housing: Added Value of Behavioral Interventions as part of an Integrated Service Delivery Model.
30 Occupancy Park, J. Y., Dougherty, T., Fritz, H., & Nagy, Z. (2019). LightLearn: An adaptive and occupant centered controller for lighting based on reinforcement learning. Building and Environment, 147, 397-414. https://doi.org/10.1016/j.buildenv.2018.10.028
Lighting_Status
31 Door_Status Malik, J., Bardhan, R., Hong, T., & Piette, M. A. (2020). Contextualising adaptive comfort behaviour within low-income housing of Mumbai, India. Building and Environment, 177, 106877. https://doi.org/10.1016/j.buildenv.2020.106877
Fan_Status
HVAC_Measurement
Light_Status
Window_Status
32 Occupant_Number Wang, Z., Hong, T., Piette, M. A., & Pritoni, M. (2019). Inferring occupant counts from Wi-Fi data in buildings through machine learning. Building and Environment, 158, 281-294. https://doi.org/10.1016/j.buildenv.2019.05.015

License:

This ASHRAE Global Occupant Behavior Database is made available under the Open Database License: http://opendatacommons.org/licenses/odbl/1.0/. Any rights in individual contents of the database are licensed under the Database Contents License: http://opendatacommons.org/licenses/dbcl/1.0/.

Acknowledgments:

The authors wish to acknowledge the generous contributions made by all dataset contributors. If you intend to use the research data contained in this database, please ensure that you give appropriate acknowledgment (e.g. citation) to the original researchers. We would also like to acknowledge the sponsorship from ASHRAE, Building Technologies Office of the U.S. Department of Energy, and kind support from IEA Annex 79 to make this possible.

Tables

Study 10 Appliance Usage Study10

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_10_appliance_usage_study10
  • 4.39 MB
  • 525600 rows
  • 5 columns
Loading...

CREATE TABLE study_10_appliance_usage_study10 (
  "date_time" TIMESTAMP,
  "electric_power_w" DOUBLE,
  "appliance_id" BIGINT,
  "room_id" BIGINT,
  "building_id" BIGINT
);

Study 10 Door Status Study10

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_10_door_status_study10
  • 3.8 MB
  • 525600 rows
  • 5 columns
Loading...

CREATE TABLE study_10_door_status_study10 (
  "date_time" TIMESTAMP,
  "door_status_0_closed_1_open" BIGINT,
  "door_id" BIGINT,
  "room_id" BIGINT,
  "building_id" BIGINT
);

Study 10 Hvac Measurement Study10

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_10_hvac_measurement_study10
  • 3.79 MB
  • 525600 rows
  • 5 columns
Loading...

CREATE TABLE study_10_hvac_measurement_study10 (
  "date_time" TIMESTAMP,
  "cooling_status_0_off_1_on" BIGINT,
  "hvac_zone_id" BIGINT,
  "room_id" BIGINT,
  "building_id" BIGINT
);

Study 10 Indoor Measurement Study10

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_10_indoor_measurement_study10
  • 5.36 MB
  • 525600 rows
  • 8 columns
Loading...

CREATE TABLE study_10_indoor_measurement_study10 (
  "date_time" TIMESTAMP,
  "indoor_temp_c" DOUBLE,
  "indoor_rh" DOUBLE,
  "indoor_co2_ppm" BIGINT,
  "indoor_voc_ppm" BIGINT,
  "indoor_air_pressure_pa" DOUBLE,
  "room_id" BIGINT,
  "building_id" BIGINT
);

Study 10 Occupancy Measurement Study10

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_10_occupancy_measurement_study10
  • 3.79 MB
  • 525600 rows
  • 4 columns
Loading...

CREATE TABLE study_10_occupancy_measurement_study10 (
  "date_time" TIMESTAMP,
  "occupancy_measurement_0_unoccupied_1_occupied" BIGINT,
  "room_id" BIGINT,
  "building_id" BIGINT
);

Study 10 Occupant Number Measurement Study10

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_10_occupant_number_measurement_study10
  • 3.79 MB
  • 525600 rows
  • 4 columns
Loading...

CREATE TABLE study_10_occupant_number_measurement_study10 (
  "date_time" TIMESTAMP,
  "occupant_number_measurement" BIGINT,
  "room_id" BIGINT,
  "building_id" BIGINT
);

Study 10 Static Info Study10

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_10_static_info_study10
  • 4.48 KB
  • 1 row
  • 6 columns
Loading...

CREATE TABLE study_10_static_info_study10 (
  "country" VARCHAR,
  "city" VARCHAR,
  "building_type" VARCHAR,
  "room_type" VARCHAR,
  "building_id" BIGINT,
  "room_id" BIGINT
);

Study 10 Window Status

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_10_window_status
  • 3.79 MB
  • 525600 rows
  • 5 columns
Loading...

CREATE TABLE study_10_window_status (
  "date_time" TIMESTAMP,
  "window_status_0_closed_1_open" BIGINT,
  "window_id" BIGINT,
  "room_id" BIGINT,
  "building_id" BIGINT
);

Study 11 Occupancy Measurement Study11

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_11_occupancy_measurement_study11
  • 662.1 KB
  • 94499 rows
  • 4 columns
Loading...

CREATE TABLE study_11_occupancy_measurement_study11 (
  "date_time" TIMESTAMP,
  "occupancy_measurement_0_unoccupied_1_occupied" BIGINT,
  "room_id" BIGINT,
  "building_id" BIGINT
);

Study 11 Static Info Study11

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_11_static_info_study11
  • 4.63 KB
  • 12 rows
  • 6 columns
Loading...

CREATE TABLE study_11_static_info_study11 (
  "country" VARCHAR,
  "city" VARCHAR,
  "building_type" VARCHAR,
  "room_type" VARCHAR,
  "building_id" BIGINT,
  "room_id" BIGINT
);

Study 12 Hvac Behavior Dict Study12

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_12_hvac_behavior_dict_study12
  • 2.5 KB
  • 9 rows
  • 2 columns
Loading...

CREATE TABLE study_12_hvac_behavior_dict_study12 (
  "col_names" VARCHAR,
  "note" VARCHAR
);

Study 12 Hvac Behavior Study12

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_12_hvac_behavior_study12
  • 58.23 KB
  • 3831 rows
  • 9 columns
Loading...

CREATE TABLE study_12_hvac_behavior_study12 (
  "co2_ppm" BIGINT,
  "temperature_indoor_c" DOUBLE,
  "relative_humidity_indoor" DOUBLE,
  "temperature_outdoor_c" DOUBLE,
  "relative_humidity_outdoor" DOUBLE,
  "solar_radiation_w_m2" DOUBLE,
  "southward_vertical_irradiance_w_m2" DOUBLE,
  "class" VARCHAR,
  "room_id" VARCHAR
);

Study 12 Shading Behavior Dict Study12

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_12_shading_behavior_dict_study12
  • 2.54 KB
  • 10 rows
  • 2 columns
Loading...

CREATE TABLE study_12_shading_behavior_dict_study12 (
  "col_names" VARCHAR,
  "note" VARCHAR
);

Study 12 Shading Behavior Study12

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_12_shading_behavior_study12
  • 56.19 KB
  • 3243 rows
  • 10 columns
Loading...

CREATE TABLE study_12_shading_behavior_study12 (
  "temperature_indoor_c" DOUBLE,
  "relative_humidity_indoor" DOUBLE,
  "indoor_illumination_lux" BIGINT,
  "temperature_outdoor_c" DOUBLE,
  "relative_humidity_outdoor" DOUBLE,
  "solar_radiation_w_m2" DOUBLE,
  "southward_vertical_irradiance_w_m2" DOUBLE,
  "shading_status_last" DOUBLE,
  "class" VARCHAR,
  "room_id" VARCHAR
);

Study 12 Window Behavior Dict Study12

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_12_window_behavior_dict_study12
  • 2.5 KB
  • 9 rows
  • 2 columns
Loading...

CREATE TABLE study_12_window_behavior_dict_study12 (
  "col_names" VARCHAR,
  "note" VARCHAR
);

Study 12 Window Behavior Study12

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_12_window_behavior_study12
  • 84.09 KB
  • 6245 rows
  • 9 columns
Loading...

CREATE TABLE study_12_window_behavior_study12 (
  "co2_ppm" BIGINT,
  "temperature_indoor_c" DOUBLE,
  "relative_humidity_indoor" DOUBLE,
  "temperature_outdoor_c" DOUBLE,
  "relative_humidity_outdoor" DOUBLE,
  "solar_radiation_w_m2" DOUBLE,
  "southward_vertical_irradiance_w_m2" DOUBLE,
  "class" VARCHAR,
  "room_id" VARCHAR
);

Study 14 Occupancy Measurement Study14

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_14_occupancy_measurement_study14
  • 662.47 KB
  • 298845 rows
  • 4 columns
Loading...

CREATE TABLE study_14_occupancy_measurement_study14 (
  "date_time" TIMESTAMP,
  "occupancy_measurement_0_unoccupied_1_occupied" BIGINT,
  "room_id" BIGINT,
  "building_id" BIGINT
);

Study 14 Outdoor Measurement Study14

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_14_outdoor_measurement_study14
  • 1.5 MB
  • 298845 rows
  • 9 columns
Loading...

CREATE TABLE study_14_outdoor_measurement_study14 (
  "date_time" TIMESTAMP,
  "outdoor_temp_c" DOUBLE,
  "outdoor_rh" DOUBLE,
  "wind_speed_m_s" DOUBLE,
  "wind_direction_deg" DOUBLE,
  "solar_radiation_w_m2" BIGINT,
  "particle_level_ug_m3" BIGINT,
  "particle_type" VARCHAR,
  "building_id" BIGINT
);

Study 14 Static Info Study14

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_14_static_info_study14
  • 4.51 KB
  • 3 rows
  • 6 columns
Loading...

CREATE TABLE study_14_static_info_study14 (
  "country" VARCHAR,
  "city" VARCHAR,
  "building_type" VARCHAR,
  "room_type" VARCHAR,
  "building_id" BIGINT,
  "room_id" BIGINT
);

Study 14 Window Status Study14

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_14_window_status_study14
  • 370.13 KB
  • 105138 rows
  • 5 columns
Loading...

CREATE TABLE study_14_window_status_study14 (
  "date_time" TIMESTAMP,
  "window_status_0_closed_1_open" BIGINT,
  "window_id" BIGINT,
  "room_id" BIGINT,
  "building_id" BIGINT
);

Study 15 Door Status Study15

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_15_door_status_study15
  • 3.63 MB
  • 799200 rows
  • 5 columns
Loading...

CREATE TABLE study_15_door_status_study15 (
  "date_time" TIMESTAMP,
  "door_status_0_closed_1_open" BIGINT,
  "door_id" BIGINT,
  "room_id" BIGINT,
  "building_id" BIGINT
);

Study 15 Hvac Measurement Study15

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_15_hvac_measurement_study15
  • 634.62 KB
  • 198288 rows
  • 5 columns
Loading...

CREATE TABLE study_15_hvac_measurement_study15 (
  "date_time" TIMESTAMP,
  "cooling_status_0_off_1_on" BIGINT,
  "hvac_zone_id" BIGINT,
  "room_id" BIGINT,
  "building_id" BIGINT
);

Study 15 Indoor Measurement Study14

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_15_indoor_measurement_study14
  • 1021.31 KB
  • 298845 rows
  • 4 columns
Loading...

CREATE TABLE study_15_indoor_measurement_study14 (
  "date_time" TIMESTAMP,
  "indoor_temp_c" DOUBLE,
  "room_id" BIGINT,
  "building_id" BIGINT
);

Study 15 Indoor Measurement Study15

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_15_indoor_measurement_study15
  • 903.46 KB
  • 146880 rows
  • 5 columns
Loading...

CREATE TABLE study_15_indoor_measurement_study15 (
  "date_time" TIMESTAMP,
  "indoor_temp_c" DOUBLE,
  "indoor_rh" DOUBLE,
  "room_id" BIGINT,
  "building_id" BIGINT
);

Study 15 Outdoor Measurement Study15

@kaggle.claytonmiller_ashrae_global_occupant_behavior_database.study_15_outdoor_measurement_study15
  • 618.1 KB
  • 62568 rows
  • 4 columns
Loading...

CREATE TABLE study_15_outdoor_measurement_study15 (
  "date_time" TIMESTAMP,
  "outdoor_temp_c" DOUBLE,
  "outdoor_rh" DOUBLE,
  "building_id" BIGINT
);

Share link

Anyone who has the link will be able to view this.